Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-509DIOD-DS1 (DS1 DIOD Trunk)
10
This test cannot be run on a trunk in any of the following conditions:
a. The trunk direction is administered as an incoming only trunk.
b. The trunk has been seized by a normal trunk call.
c. The trunk is administered with maintenance test disabled.
Table 10-138. TEST #314 DS1 CO Dial Tone Seizure Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be in use on a valid call. Use the
status trunk command to determine when the port is
available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use
the status trunk command to determine when the port
is available for testing.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, and the port is not in
use, escalate the problem.
1005 ABORT Test failed due to incompatible configuration
administered in trunk group form.
1. Look at the trunk group administration form and see
whether the trunk is incoming only, port 24 on a DS1
Interface with common control channel signaling, or
an automatic CO type such as FX. Under any of
these conditions this is a normal abort.
1018 ABORT Test has been disabled via administration.
1. Verify that the ‘‘Maintenance Tests’’ field on the
Trunk Group Form is set to ‘‘n.’’ To enable the test,
issue the change trunk-group x command where
‘‘x’’ equals the number of the trunk group to be
tested. Then change the entry in the ‘‘Maintenance
Tests’’ field on the form to ‘‘y.’’
2. Repeat the test.
Continued on next page