DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-44ALARM-PT (ALARM PORT)
10
ALARM-PT (ALARM PORT)
The Alarm Port Maintenance Object provides on-board maintenance for an
analog line port that is administered as an external device alarm port. Tests are
provided to verify the analog line port’s ability to detect an external device alarm.
The External Device Alarm (EXT-DEV) Maintenance Object is used for the
off-board external device alarm.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the
carrier designation (for example, A, B, C, D, or E); SS is the address of the slot
in the carrier where the circuit pack is located (for example, 01, 02, ..., etc.); and
pp is the 2-digit port number (for example, 01).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
Full Name of MO
ALARM-PT MIN test port PCSSpp l Alarm-Port
ALARM-PT WRN test port PCSSpp sh Alarm-Port