DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-324CO-DS1 (DS1 CO Trunk)
10
1005 ABORT Test failed due to incompatible configuration
administered in trunk group form.
1. Verify the following fields on the trunk group
administration screen: Is trunk direction incoming
only? Is trunk the port 24 of the DS1 Interface circuit
pack while common control channel signaling is
specified? Is trunk group type the automatic CO (for
example, FX)?
2. If the trunk has been administered using the above
information, then this test should abort.
1018 ABORT Thest is disabled via tranlsation. You may want to
determine why the test has been disabled before you
enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk
Group’ form is set to ’n’. To enable the test, issue the
change trunk-group x command (x equals the
number of the trunk group to be tested). Then,
change the entry in the ’Maintenance Test’ field on
the form to ’y’.
2. Repeat the test.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in the Hardware Error Log. If
present, refer to DS1-BD (DS1 Trunk Circuit Pack)
Maintenance documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
1040 ABORT The test was aborted because this port may be an
access endpoint.
1. Verify that this port is an access endpoint by issuing
the display port command.
2. If the port has been administered as an access
endpoint, then this is a normal abort.
Table 10-91. TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page