DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-126ANNOUNCE (Announce)
10
32014 Command timed out on the standby processor [286 systems]. This
could present problems.
1. Check the error and alarm logs for errors and alarms that are
logged against the STBY-SPE (Standby SPE) [286 systems].
32015 Time of day not set.
1. Set the time of day, and reenter the save/restore
announcements command.
32016 Internal System errors.
Check for any other ANNOUNCE errors and take corrective action.If
there are no other announcements errors, do the following:
1. Retry the command at two minute intervals a maximum of three
times.
2. If the save/restore announcements command fails, escalate
the problem.
Table 10-42. Aux Data Error Codes and Recommended
Repair Procedures — Continued
Aux
Data Description/ Recommendation
Continued on next page