Page 8-393status bri-port
8
Output
Port: This field specifies the physical address of the ISDN-BRI port.
Service State: This field specifies whether the ISDN-BRI port is "in-service" or
"out-of-service."
Maintenance Busy?: This field specifies whether there is any maintenance testing
being performed upon the ISDN-BRI port ("yes" or "no").
Layer 1 State: This field contains the layer 1 (physical) state of the BRI on the
port. Valid states are "activated," "pend-activation," and
"deactivated."
The "activated" state means layer 1 frames are being passed
between the port and BRI endpoints.
The "pend-activation" state specifies that the port has been
placed in-service, the layer 1 interface device has been
turned on, layer 1 frames are being sent to the BRI endpoints
connected to this port, but the BRI endpoints are not
responding.
The "deactivated" state means that the layer 1 interface
device on the BRI has been turned off due to the port going
out-of-service.
TEI Value The Terminal Endpoint Identifier(TEI) is a layer 2 addressing
parameter used by the switch to pass information over the
point-to-point signaling link to and from BRI endpoints. Each
point-to-point signaling link has a TEI associated with it. This field
displays the value of this addressing parameter. This value is in
the range from 0 to 127.