DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-499DIOD-DS1 (DS1 DIOD Trunk)
10
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Hardware Error Log Entries and Test to Clear
Values
out-of-service The trunk is in a deactivated state and
cannot be used for either incoming or
outgoing calls.
in-service The trunk is in an activated state and can
be used for both incoming and outgoing
calls.
disconnect (ready-for-service) The trunk is in an activated state but can
only be used for an incoming call.
DS1 DIOD Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test trunk <grp>/<mbr>
1(a) 57408
1(a) 57487
57476
57477
57485
15(b) Any Port Audit and
Update Test (#36)
18(c) 0 busyout trunk
<grp>/<mbr>
WARNIN
G
OFF release trunk
<grp>/<mbr>
130(d) None WARNIN
G
ON test trunk <grp>/<mbr>
257(e) 57392 DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
513(f) 57393 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
2
OFF
769(g) 57484
1025(h) 51200
1025 DS1 CO Dial Tone
Seizure Test (#314)
MIN/
WRN
3
OFF test trunk <grp>/<mbr>
r 2
Continued on next page