DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1632UDS1-BD (UDS1 Interface Circuit Pack)
10
1313 FAIL The TN464F UDS1 circuit pack could not deactivate the
loopback through the Customer Loopback Jack.
1. Retry the
test ds1-loop PCSS
end-loopback/span-test
command at 1-minute
intervals for a maximum of 5 times.
2. If the test continues to fail with this error code,
escalate the problem.
1314 FAIL The TN464F UDS1 circuit pack could not deactivate the
loopback through the far-end CSU.
1. Make sure that the far-end DS1 is installed if the
far-end CSU is a 120A AT&T CSU Module.
2. Retry the
test ds1-loop PCSS
end-loopback/span-test
command at 1-minute
intervals for a maximum of 5 times.
3. If the test continues to fail with this error code,
escalate the problem.
PASS The active long-duration loopback or span test on the
TN464F circuit pack was successfully terminated.
Table 10-476. TEST #1216 End Loopback/Span Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page