DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-635E-DIG-STA (Emulated Digital Line)
10
Table 10-183. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 ABORT System technician may have busied out the port.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port with the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port is busy
with a valid call. Use display port PCSSpp/PCSSpp to determine the
station extension or attendant number of the port. Use status station or
status attendant to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. Wait until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1392 ABORT This is currently a TTI port, and the test cannot execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config
command (the display shows a t for the port).
2. If either list config or display port indicates that the port is
not
a TTI
port, escalate the problem. If both commands indicate that the port is a
TTI port, the abort is correct, and no action is necessary.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page