Maintenance Commands and Trouble-Clearing Aids
Page 8-125display events
8
Output
See
DEFINITY Communications System Generic 3 Call Vectoring and Expert
Agent Selection (EAS) Guide
, 555-230-520, for more information on how to
interpret this report. In particular, the Event Data 2 field will be associated with
possible causes and repair strategies for the event.
The following example shows the input form for display events:
Event Type A number from 50000 to 50999 that identifies what type of vector event
occurred.
Event
Description
A text string describing the event.
Event Data 1 If in the format
number
/
number
such as ‘‘200/10’’, this indicates the
vector number and step number associated with the event. If in the
format ‘‘Split
number
’’ such as ‘‘Split 2’’, this indicates the split number.
Event Data 2 Additional data concerning the event encoded as a hex number.
First Occur The date and time when the vector event first occurred.
Last Occur The date and time when the vector event last occurred.
Evnt Cnt The total number of times, up to 255, that vector events of this type
have occurred.
display events Page 1 of 1 SPE B
EVENT REPORT
The following options control which events will be displayed.
EVENT CATEGORY
Category: vector
REPORT PERIOD
Interval: _a_ From: __/__/__:__ To: __/__/__:__
SEARCH OPTIONS
Vector Number: ___
Event Type: _____