Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-169BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
10
Table 10-55. TEST #618 BRI Port Local LAN Loop Around
Error
Code
Test
Result Description/ Recommendation
1015 ABORT The port is not in the out-of-service service state.
1. Display the BRI Port Status form via the status
bri-port PCSSpp command to determine which
stations or adjuncts are on this port.
2. Use the extension shown on this form in the status
station command to determine if the station or
adjunct is in use.
3. If it is in use, wait until it is idle, and then busyout the
port (using the busyout port PCSSpp command) to
place it in the out-of-service state and repeat this
test.
!
WARNING:
Since the "busyout" command is destructive,
execution of this command prior to the port being
idle causes all calls associated with BRI endpoints
and all transactions associated with ASAI or AT&T
adjuncts on the port to be torn down. Note that
third party calls established by an ASAI or AT&T
adjunct remain connected even though the port is
taken out-of-service.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the
BRI Port Local LAN Loop Around Test to verify the
repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the
BRI Port Local LAN Loop Around Test to verify the
repair.