DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-302CLSFY-PT (Call Classifier Port)
10
1002 ABORT The system could not allocate time slots for the test
connection. This situation could occur when the system
is heavily loaded. If the system is not heavily loaded,
then test the TDM-BUS via the test tdm [1|2] command.
Refer to the TDM-BUS (TDM Bus) Maintenance
documentation for details.
1. Retry the command at one minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a Tone-Clock circuit pack
for the test connection. This situation could occur when
the system is heavily loaded or if a Tone-Clock circuit
pack is not present in the port network when this test is
executed.
1. Verify the existence of a Tone-Clock circuit pack in
the same port network.
2. If a Tone-Clock circuit pack is missing, install one in
the same port network.
3. Allow approximately one minute for the Tone-Clock
circuit pack maintenance to run on the newly
inserted Tone-Clock circuit pack.
4. Retry the command at one minute intervals a
maximum of five times.
5. If the test continues to abort, escalate the problem.
Table 10-86. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page