Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1504TONE-PT (Tone Generator)
10
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
SAKI
Sanity Test
, for example, you may also clear errors generated from other tests in
the testing sequence.
Use the list configuration control command to find the Tone-Clock Circuit Pack
Code of the system. Then look for the Short and Long Test Sequences according
to the Tone-Clock Circuit Pack Code.
For a system with a TN756 Tone-Clock Circuit Pack
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation
for descriptions of these tests.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) Maintenance documentation
for descriptions of these tests.
c. Refer to Dual Tone Multifrequency Receiver Port (TTR) (DTMR-PT) or
General Purpose Tone Detector (CPTR) (GPTD-PT) Maintenance
documentation for descriptions of this test.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long
Test
Sequence D/ND
1
SAKI Sanity Test (#53) (a) X D
Clock Health Inquiry Test (#46) (b) X X ND
Control Channel Loop Around Test (#52) (a) X X ND
Tone Detection Verification Test (#42) (c) X X ND
Tone Detector Audit/Update Test (#43) (c) X X ND
Tone Generator Crosstalk Test (#90) X ND
Tone Generator Transmission Test (#40) X X ND
Tone Generator Audit/Update Test (#41) X X ND