DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-898MET-LINE (MET Line)
10
Table 10-256. TEST #60 MET Line Station Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT This port may have been busied out by system
technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If this error type is present, then
release the port via the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
2 ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
3 ABORT Station is in ready-for-service or out-of-service state.
This may be due to wiring or an unplugged or defective
set.
1. Make sure terminal is connected and the wiring is
correct.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page