DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1507TONE-PT (Tone Generator)
10
Table 10-450. TEST #40 Tone Generator Transmission Test
Error
Code
Test
Result Description/ Recommendation
None ABORT The system was not able to allocate all the resources
needed for this test or there was an Internal System
Error.
1 ABORT The system could not allocate all the resources needed
to test the DTMF tones.
1001 ABORT The system was not able to put the tone generation
facility in the appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test
connection. This can happen when the system is heavily
loaded. If the system is not heavily loaded, then test the
TDM Bus via the test tdm port-network PN# command.
Refer to TDM-BUS section for details.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, follow normal
escalation procedures.
1003 ABORT The system could not allocate a tone receiver for the test
connection. This can happen when the system is heavily
loaded or there is not a Tone Detector circuit pack in the
port network where this test is being executed.
1. Make sure there is a Tone Detector circuit pack in
the same port network.
2. If a Tone Detector circuit pack is missing, install one
in the same port network.
3. Allow approximately 1 minute for Tone Detector
maintenance to run on the newly inserted Tone
Detector circuit pack.
4. Retry the command at 1-minute intervals a maximum
of 5 times.
5. If the test continues to abort, follow normal
escalation procedures.
Continued on next page