DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1379TAPE-DAT (Tape Consistency)
10
Table 10-419. TEST #421 Tape Data Consistency Check Test
Error
Code
Test
Result Description/ Recommendation
0 ABORT The test timed out without completing. This error can occur when the
system is heavily loaded and the test is not allocated sufficient time to run.
1. Rerun the test when the system is less busy and is not running standby
maintenance.
1029
1030
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance documentation for a
description of these error codes.
9005 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35498 ABORT Difficulty was encountered trying to send information between the SPEs.
35512 ABORT The Standby SPE cannot be put into maintenance mode.
1. Resolve all DUPINT (Duplication Interface Circuit Pack), SHDW-LNK
(Memory Shadowing Link), SHDW-CIR (Common Shadow Circuit), and
STBY-SPE (Standby SPE) alarms.
2. Retry the command.
35514 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35534 ABORT Could not allocate the tape drive (could be active or standby) because
another tape operation was in progress.
1. Wait 10 minutes, and retry the command.
Continued on next page