DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1477TIE-TRK (Tie Trunk)
10
1919 ABORT Unexpected far end release
1. The problem is with the far end system; a technician
at the far end should test the test line (TN771 or
ADFTC).
1920 ABORT No response from far end.
1. The problem is with the far end system; a technician
at the far end should test the test line (TN771 or
ADFTC).
1921 ABORT No data returned from far end.
1. The problem is with the far end system; a technician
at the far end should test the test line (TN771 or
ADFTC).
1922 ABORT Steady, unidentifiable tone from far end
1. See actions for error code 1905.
1923 ABORT Broadband energy detected from far end (such as voice
or announcement).
1. See actions for error code 1905.
1924 ABORT No test tone from far end
1. See actions for error code 1905.
1938 ABORT Near-end self test failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1939 ABORT Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1940 ABORT Far end noise self check failed.
1. The problem is with the far end system; a technician
at the far end should test the test line (TN771 or
ADFTC).
Table 10-447. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation