DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-354CO-TRK (CO Trunk)
10
Transmission Test (#844-848)
This test is non-destructive.
NOTE:
Tests #844-848 are not supported on a International switch.
These tests are run by the Automatic Transmission Measurement System
(ATMS). They are not part of the long or short trunk test sequences. Instead, they
are run on demand with the test analog-testcall command or as part of ATMS
scheduled testing.
PASS This test passed. Translation information was
successfully updated on the circuit pack. User-reported
troubles on this port should be investigated by using
other port tests and by examining trunk or external
wiring. If the trunk is busied out, the test does not run,
but returns PASS. To verify that the trunk is in-service:
1. Enter status-command to verify that the trunk is
in-service. If the trunk is in-service, no further action
is necessary. If the trunk is out-of-service, continue
to Step 2.
2. Enter release-trunk command to put trunk back into
in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no
board).
1. Check to ensure that the board translations are
correct. Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should
re-establish the linkage between the internal ID and
the port.
Table 10-98. TEST #36 Port Audit Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page