DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1112PMS-LINK (Property Management System Link)
10
l. Error Type 2817:
Aux values of concern:
m. The link was taken down by the switch because the threshold for
application protocol violations has been exceeded by the PMS. The
protocol never started and messages were received and/or messages
were received in a state in which they were not expected. (Refer to Error
Type 2817 for recommended strategy.)
n. Link was taken down by the switch because the threshold for link protocol
violations has been exceeded by the PMS. PMS is sending "garbage" to
the switch.
10x The PMS violated the application protocol. The first
message after a request to initiate a database exchange
was not the start of a database exchange. The message
is processed. If this error type with this aux data value
recurs frequently (that is, more than once a month), then
advise the customer to call the vendor of the PMS to
check out the PMS device. Once the PMS Link is
successfully established, this error disappears from the
Hardware Error Log. See Note.
20x The PMS violated the application protocol. The start of a
database exchange was received in a state in which it
was not expected. The message is ignored. If this error
type with this Aux data value recurs frequently (that is,
more than once a month), then advise the customer to
call the vendor of the PMS to check out the PMS device.
Once the PMS Link is successfully established, this error
disappears from the Hardware Error Log. See the next
Note.
30x The PMS violated the application protocol. The end of a
database exchange was received when no exchange
was in progress. The message is ignored. If this error
type with this Aux Data value recurs frequently (that is,
more than once a month), then advise the customer to
call the vendor of the PMS to check out the PMS device.
Once the PMS Link is successfully established, this error
disappears from the Hardware Error Log.
NOTE:
The PMS should be assessed for adherence to the
PMS/PBX protocol specifications. No alarm is
raised against this error.