Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-757HYB-LINE (Hybrid Line)
10
Table 10-211. TEST #59 Hybrid Line Remote Digital
Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT A request for a remote station audit aborted even though
all internal resources were correctly allocated.
1. Look in the error log for error type 18 (port busied
out) for this port. If this error type is present, release
the port via the release port UUCSSpp command or
the release station extension command, and then
run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a
maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call. Use the
display port PCSSpp command to determine the
station extension number of the port. Use the status
station command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids" for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not
busied out.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page