DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-720FL-DATA (Flash Data Consistency)
10
a. The Aux Data field records which SPE was active at the time the Flash
Data Consistency Test failed. An "8" in the log refers to carrier A and a "16"
refers to carrier B.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
Memory Card Insertion Test,
for example, you
may also clear errors generated from other tests in the testing sequence.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
1. D = Destructive; ND = Nondestructive
292,
324,
388,
420,
452
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
12 Volt Power Supply Test (#701) (b) X X ND
Memory Card Insertion Test (#695) (a) X X ND
Memory Card Format and Read Test (#696) (a) X X ND
Memory Card Match Test (#697) (a) X X ND
Memory Card Write-Protected Test (#698) (a) X X ND
Memory Card Directory Recovery Test (#699) (a) X X ND
Memory Card Translation Data Integrity Test (#694) (a) X ND
Memory Card Erase/Write/Read Test (#693) (a) X ND
Flash Data Consistency Test (#421) (c) X ND
Table 10-204. Flash Data Consistency Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page