DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-663EXP-INTF (Expansion Interface Circuit Pack)
10
Notes:
a. Expansion Interface (EI) circuit pack has been busied out by system
technician.
b. EI circuit pack has been administered on the Circuit Pack form, but has
not been physically inserted into the system. Insert the circuit pack.
c. A wrong circuit pack is inserted in the slot where this circuit pack is
logically administered. To resolve this problem, either remove the wrong
circuit pack and insert the logically administered circuit pack OR use the
change circuit-pack command to re-administer this slot to match the
circuit pack inserted.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
3585 (n) 0 None WRN OFF
3841 (o) Any None MIN OFF (See Note q.)
3842 (p) Any None MIN OFF (See Note q.)
10000 (r) 0 None
10001 (s) 0 None
10002 (t) 0 None
10003 (u) 0 None
10004 (v) 0 None
11000 (w) 0 None
11000 (x) 2 None
11000 (y) 3 None
11000 (z) 4 None
11000
(aa)
5 None
11000
(ab)
8 None
11001
(ac)
0 None
Table 10-190. Expansion Interface Circuit Pack Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page