Maintenance Object Repair Procedures
Page 10-1438TIE-DS1 (DS1 Tie Trunk)
10
FAIL
(con’t.)
6. Replace the circuit pack.
NOTE:
If the conference circuit test fails for all ports on a
circuit pack, a -5 volt power problem is indicated.
If a TN736 or TN752 power unit circuit pack is
present, either the 631DB AC power unit or the
676B DC power unit may be defective. (The
631DB power unit is used in a medium cabinet
powered by an AC source. The 645B power unit is
used in a medium cabinet powered by a DC
power source.) The system may contain a TN736
or TN752 power unit or a 631DB AC power unit,
but not both types of power units. To investigate
problems with a 631DB AC power unit, refer to the
CARR-POW (carrier port power unit for
AC-powered systems) Maintenance
documentation. To investigate problems with a
645B DC power unit, refer to the CARR-POW
(carrier port power unit for DC-powered systems)
Maintenance documentation. If a red LED on
TN736 or TN752 power unit circuit pack is on,
replace the pack.
PASS The port can correctly conference multiple connections.
User-reported troubles on this port should be
investigated using other port tests and by examining
station, trunk, or external wiring.