DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1058PI-LINK (Processor Interface Link)
10
f. This error message indicates that the TN765 Processor Interface circuit
pack could not transmit the message the software sent to it. See the "Link
Recovery" section if the error continues. This is a normal error during "hot
start" SPE-interchanges.
g. Excessive resets on the link. Usually indicates that the remote end is down
or the physical connection is broken. A warning alarm is raised initially,
followed by a Major alarm if the problem is not cleared. See the "Link
Recovery" section.
h. Excessive I-frame retransmission. Could indicate a noisy link. Recover as
in previous note. Aux values indicate the retransmission rate per minute.
See the "Link Recovery" section.
i. If the Aux Data value is 9, then the destination circuit pack (DIG-BD or
DS1-BD) is not inserted. Otherwise, DS1 maintenance detected a
hardware failure. (DS1 cable disconnected, loss of signal, DS1-BD
problems.) Not a Processor Interface Link problem. Check DS1-BD
maintenance. Only applicable to ISDN links. Aux value useless. Once the
DS1 signal is restored, maintenance automatically restarts the Processor
Interface Link. To hasten this process, test the appropriate DS1 Interface
circuit pack via test board PCS command. When Test #138 (loss of
signal) passes, the Processor Interface Link recovers shortly.
In addition to an indication that the link failed to establish the PI-LINK 2561
AUX_Data, the hardware error log is also updated. This error may indicate
two possible conditions:
1. A failure to detect the DTR from the peripheral.
When the DTR is not detected by the data module the AUX_Data is
set to 40. This indicates that the problem is most likely with the
peripheral or the connection to the peripheral.
2. A time-out on the EIA interface query request to the data module.
32841 Call went over the trunk and received ring back but did not
receive modem answer tone. Check the remote destination
for automatic answering.
65528 Administration problem; check all administration.
65532 Call setup timed out; retry, and check destination. If the
destination is an adjunct (CMS, AUDIX, etc.), then check if
the terminal ready light is lighted on the PDM. If not, then
the adjunct is down. If the destination is another PBX, then
the PBX might be restarting. Retry.
65535 Link specified is out-of-range (1 through 8).
Continued on next page