DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-466status isdn-testcall
8
For the following output example, the command status idsn-testcall 80/1 was
entered.
Feature Interactions
If the bit error rate or block error rate is greater than zero, the ISDN-PRI trunk
"may" be in a troubled state. Based on the statistical information displayed on the
terminal, it can be decided to take the ISDN trunk out of service. This is
Duration Specified The duration specified in minutes for how long the test call
should run. Valid durations are 1-120 (minutes) or blank (to
indicate the default amount of 10 seconds was used to run the
test).
Duration of Test The duration specified in minutes for how long the test call has
been running. A blank indicates that the default amount of time
was used to run the test.
Reason of Termination The reason of termination indicates why the test call has
terminated. Valid reasons of termination are "finished,"
"canceled," "overflow," "no bits," "transmission," "internal fail,"
"data corrupt," "call dropped," "call rejected," and "in progress."
A termination reason of "finished" means the test finished in the
specified time. A termination reason of "canceled" means the
test call has been canceled with the "clear isdn-testcall"
command. A reason of "overflow" denotes that the bits
transmitted have overflowed buffer allocation. A reason of "no
bits" means that no bits have been received because the
ISDN-PRI test call circuit connection is bad. A reason of
"transmission" means there has been a data transmission
interruption, probably caused from a power hit. A termination
reason of "call dropped" indicates that the call dropped due to
abnormal termination, or it couldn’t cut-through to the other
side. A termination reason of "call rejected" means the
originating call was not set up properly. A termination reason of
"internal fail" specifies that there is an internal error on the
Maintenance/Test circuit pack. A reason of "in progress" means
the test is still running and a reason of "data corrupt" is used for
any other error condition.
status isdn-testcall 80/1 Page 1 of 1 SPE A
ISDN TESTCALL STATUS
Bit Number Block Number Duration Reason
Error Of Error Of Start Duration Of Of
Port Rate Bits Rate Blocks Time Specified Test Termination
1B1401 0EE0 4EE7 0EE0 6EE2 25/12:36 120 100 in progress