DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-139display synchronization
8
Error Messages
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Output
For the following output example, the command display synchronization was
entered.
Stratum: This field specifies the synchronization stratum that is used. The only
possible entries are "3" and "4."
Primary: This field designate the first choice system synchronization source. A
blank entry means no synchronization. This field is valid only if stratum 4
synchronization is specified.
Secondary: This field designate the second choice system synchronization source.
A blank entry means no synchronization. This field is valid only if stratum
4 synchronization is specified.
Location: The circuit pack location (cabinet-carrier-slot) of all administered DS1
circuit packs are listed here.
Name: If a user defined name is administered for the DS1 circuit pack, it will be
displayed here. Blank means no user defined name was given to this
DS1 circuit pack.
Slip: If the DS1 circuit pack has slip alarm, this field will show ’y’. Otherwise it
will show ’n’.
Port Network: This field is only valid for stratum 3 synchronization. The field specifies
the port network that supplies synchronization via the tone clock circuit
pack.