DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1219S-SYN-PT (Speech Synthesis Port)
10
Table 10-378. TEST #165 Speech Synthesis DSP Tone Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call and
therefore unavailable for certain tests. You must wait
until the port is idle (yellow LED if off) before retesting.
1. If the port is idle retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1001
1002
1003
ABORT System resources required to run this test are not
available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1021 ABORT The 440-Hz tone was not detected by the Tone Detector
circuit and inter-digit time-out has occurred on the Tone
Detector circuit.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, verify all Tone Detector
circuit packs in the system are functioning correctly
by checking the Error Log and using the test board
PCSS long command. Replace any faulty Tone
Detector circuit packs and repeat the test.
3. If the test continues to abort, replace the Speech
Synthesis circuit pack.
Continued on next page