Page 10-440DID-DS1 (DS1 DID Trunk)
10
Port Audit and Update Test (#36)
This test sends port level translation data from the switch processor to the DS1
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of the trunk as kept in the DS1 Interface circuit
pack and in the switch software.
PASS The port can correctly conference multiple connections.
User-reported troubles on this port should be investigated using
other port tests and by examining station, trunk, or external
wiring.
NOTE:
This test always passes for TN712 Analog circuit packs
prior to Vintage 14 and for TN742 prior to Vintage 4.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use
the lIst config command and resolve any problems that are
found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish
the linkage between the internal ID and the port. If this is not
the case, check to see that there is a valid board inserted.
Table 10-122. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page