Page 10-25ADX8D-PT (AUDIX Digital Port)
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times.
Voice and Control Channel Local Loop Test (#13)
This test checks the information and control channels between the Switch
Processing Element (SPE) and the DEFINITY AUDIX port circuit. First, the
primary information (voice) channel loop back test is run.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors. Refer to “TDM-BUS” to diagnose any active TDM-BUS
errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic,
try (a).
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors. Try (a).
1004 ABORT The port was put in use during the test. The test has been aborted. Use the
display port PCSSpp command to determine the voice port extension of the
port. Use the status station command to determine the service state of the
port. If the port is in use, wait until the port is idle before testing.
1020 ABORT Test disabled by background testing. Use the status station command to
determine when the voice port is available for testing.
2000 ABORT Response to the test request was not received within the allowable time
period. Try (a).
1
2
FAIL The NPE of the tested port is transmitting in error. This causes noisy and
unreliable connections. Failure code 1 indicates that the Crosstalk test failed
on the primary channel. Failure code 2 indicates that the Crosstalk test failed
on the secondary channel.
1. Replace the circuit pack .
PASS The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat this test up to a
maximum of 10 times to make sure it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-10. TEST #9 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page