DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-507DIOD-DS1 (DS1 DIOD Trunk)
10
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack
and in the switch software.
2053 ABORT At least one of the following errors is found on the DS1
circuit pack:
1281Loss of signal
1793Blue Alarm
2049Red Alarm
2305Yellow Alarm
1537Hyperactivity
Look for the above error types in the Hardware Error Log
and follow the procedures given in the appropriate
DS1-BD or UDS1-BD maintenance documentation for
the listed error types.
FAIL The NPE of the tested port did not conference the tones
correctly. This will cause noisy and unreliable
connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections.
User-reported troubles on this port should be
investigated by using other port tests and by examining
station, trunk, or external wiring.
Table 10-136. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page