Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-995OPS-LINE (DS1 OPS Line)
10
1000 ABORT The test was aborted because system resources
required to run this test were not available. The port may
be busy with a valid call. Use the display port PCSSpp
command to determine the station extension of the port.
Use the status station command to determine the
service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1006 ABORT The test was aborted because the station is out of
service. This condition may be accompanied by an error
type 18 entry in the error log. You may want to determine
why the station was taken out of service. (When stations
are taken out of service by maintenance software, the
problems that preceded that point must be cleared.)
1. Use the status station command to check the
service state of the port. If the port is indeed out of
service, enter the release station command to bring
the station back into service.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
3. If the test continues to abort and the service state
indicates that the station is in service and idle,
escalate the problem.
Table 10-287. TEST #36 Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page