DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-322reset maintenance
8
Error Messages
If the cabinet entered is non numeric or not within a valid range, the following
message will be displayed:
Cabinet number out of range; Enter 2 - 3
If the length of the user entered parameter exceeds three (3), or is in any other
way invalid, the following message will be displayed:
Entry invalid
If the command entered is in conflict with another currently executing command,
then a message displays showing the login ID of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
Output
For the following output example, assume that the command that was entered is
"reset maintenance 02a."
Feature Interactions
Running the command from the EPNSAT, will cause the SAT to be dropped
before the reset results can be displayed. In this case, the user should examine
the error and alarm logs for "MAINT" entries to determine if the reset failed.
Port The port address (cabinet-carrier-slot) of the MO being reset.
Maintenance Name "MAINT" for the EPN maintenance circuit pack.
Alt. Name Always blank for this command.
Result The result of the reset -"PASS," "ABORT," "FAIL."
Test No. The test number for this command will always be 306.
Error Code A system-generated number that tells why the reset failed or
aborted. A detailed list of the codes can be in the "Reset
Commands" section of this chapter.
reset maintenance 02A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A MAINT 306 PASS
Command successfully completed