DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-209BRI-SET, ASAI-ADJ, BRI-DAT
10
BRI XID Test (#628)
This test checks the D-channel connection between the SPE and the endpoint or
adjunct.
In this test, a D-channel XID frame is sent to the endpoint or adjunct over the
point-to-point signaling link. The test passes if the endpoint or adjunct responds
with a Layer 2 XID-RESPONSE frame.
This test must be administered to not run in the station administration form for
ports on a TN2208.
PASS The endpoint has responded to the switch activate and
deactivate loop back application messages. Data has
been detected on the looped back channels.
1000 ABORT Could not seize the endpoint or B-channels for test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-67. TEST #627 BRI Remote Loop Back — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page