DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-350CO-TRK (CO Trunk)
10
1018 ABORT The test was disabled via administration. Verify that the
’Maintenance Test’ field on the ’Trunk Group’ form is set to
’n’. To enable the test, issue the ’change trunk-group x’
command (x equals the number of the trunk group to be
tested). Then, change the entry in the ’Maintenance Test’
field on the form to ’y’.
1. Retry the command at 1 minute intervals a maximum of 5
times.
2. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test was not received within the allowable
time period.
1. Retry the command at 1 minute intervals for a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to run
this test.
1. Retry the command at one-minute intervals a maximum
of five times.
2. If the test continues to abort, escalate the problem.
Table 10-97. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page