DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-473DIG-LINE (Digital Line)
10
A confirmation is returned if the download request is accepted. A busy
tone is returned if the request is made from a different station when the
target station is off-hook.
The first three green call appearance LEDs on the 84xx 603x terminal will
be turned on for three seconds if the station was successfully downloaded
as a result of an entry of a Refresh Terminal Parameters Facility Access
Code. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or
demand download actions. As described below, the "status station" and
"status attendant" screens can be used to check the download status of a
specified terminal.
Status of Parameter Downloads
The "status station" and "status attendant" screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the Download Status field.
The possible download states are:
Possible reasons for terminal being not downloaded include:
— Terminal is off-hook.
— Terminal detected a bad checksum.
— Terminal detected a bad or missing EEPROM (refer to hardware error log).
— Terminal is busy programming data from a previous PROGRAM message.
— Terminal is in the Programming Disabled state.
— Terminal is in the Local Program Options Mode.
— Terminal is disconnected or out of service (use status station command).
Table 10-128. Terminal Download Status
Status Terminal Down Load State
Complete Terminal successfully downloaded sometime in the past.
Pending System waiting to download the terminal. This may
require the execution of a background periodic test
which could take more than an hour. A demand
download as described above may also be used to
initiate an immediate download.
Not Applicable Not a programmable terminal.