Page 10-1013PDMODULE, TDMODULE (Data Module)
10
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat the test at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
Tone Detectors present or some Tone Detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV (TTR Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the command at
one-minute intervals for a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display port PCSSpp
command to determine the data module extension.
Then use status data module command with the
extension number to determine the service state of the
data module. If the service state indicates that the data
module is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-290. TEST #13 Information and Control Channel
Local Loop Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page