DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-350set options
8
■ Hybrid Lines (HYB-LINE)
■ MET Lines (MET-LINE)
■ ISDN-BRI Lines (BRI-PORT, BRI-SET)
Trunk maintenance is characterized by an escalation of a Minor alarm to a Major
alarm if more than 75 percent of the members of the trunk group are alarmed. If
the option for the trunk category is set to "warning," "minor," "report," or "no," this
no longer happens. Maintenance removes an individual trunk member
out-of-service according to the normal criteria used for Major and Minor alarms.
Trunk MOs Affected By This Command:
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-reported problems.
■ Auxiliary Trunks (AUX-TRK)
■ Central Office Trunks (CO-TRK)
■ Direct Inward Dialing Trunks (DID-TRK)
■ Direct Inward and Outward Dial Trunks (DIOD-TRK)
■ DS1 Central Office Trunks (CO-DS1)
■ DS1 Direct Inward Dialing Trunks (DID-DS1)
■ DS1 Tie Trunks (TIE-DS1)
■ ISDN Trunks (ISDN-TRK)
■ Tie Trunks (TIE-TRK)
Circuit Pack MOs Affected By This Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-reported problems.
NOTE:
Trunks that are not members of Trunk Groups, (e.g. PCOLs) are
downgraded according to the alarm severity of group one.
■ DS1 Interface Circuit Pack (DS1-BD)
Adjunct-Related MOs Affected By This Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-reported problems.