DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-303CLSFY-PT (Call Classifier Port)
10
2006 ABORT This abort code indicates that the active Tone-Clock
circuit pack might not be functioning properly. If there is
more than one Tone Detector circuit pack in the system,
then the problem can be either with the Tone-Clock
circuit pack or the Tone Detector circuit pack. This could
also be caused by the companding mode administered
for the system not matching that of the Tone Detector
circuit pack [G3iV2-386].
1. [G3iV2-386] Make sure that the companding mode
of the system matches that of the Tone Detector
(TN748 for Mu-law systems and TN420 for A-law
systems).
2. Test the active Tone-Clock circuit pack in the port
network. This test is being executed via the test
tone-clock qualifier system technician command.
("qualifier" is the carrier of the active Tone-Clock
circuit pack to be tested. Valid qualifiers are: a, b,
1a, 1b, 2a, and 2b.) Refer to the TONE-BD
(Tone-Clock Circuit Pack) Maintenance
documentation for details.
3. Retry the command at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-86. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page