DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1497TONE-BD (Tone-Clock Circuit Pack)
10
For a system with a TN756 Tone-Clock Circuit Pack
:
a. Refer to XXX-BD (Common Port Circuit Pack) documentation for
descriptions of these tests.
b. Refer to TONE-PT (Tone Generator) documentation for descriptions of
these tests.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short
Test
Sequence
Long
Test
Sequence D/ND
1
SAKI Sanity Test (#53) (a) X D
Clock Health Inquiry Test (#46) X X ND
Control Channel Loop Around Test
(#52) (a)
XXND
Tone Detection Verification Test (#42)
(b)
XXND
Tone Detection Audit/Update Test
(#43) (b)
XXND
Tone Generator Crosstalk Test (#90) (b) X ND
Tone Generator Transmission Test (#40)
(b)
XXND
Tone Generator Audit/Update (#41) (b) X X ND