DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-446DID-TRK (DID Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
DID Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None WRN OFF
1 (b) 57476 None WRN OFF
1 (c) 57477 None WRN OFF
1 (d) 57483 None WRN OFF
15 (e) Any Port Audit Update
(#36)
18 0 busyout trunk
<grp/mbr>
WRN OFF release trunk <grp/mbr>
130 (f) None WRN ON test trunk <grp>/<mbr>
257 (g) 57472 None WRN OFF
257 (h) 57473 None WRN OFF
257 (i) 57474 None WRN OFF
257 (j) 57475 None WRN OFF
513 (k) 57392 None MAJ/MIN/
WRN
2
OFF
510 (l) 57393 None
769 Any Port Diagnostic
(#35)
MAJ/MIN/
WRN
2
ON test port PCSSpp r 3
1025 Loop Around and
Conference (#33)
MAJ/MIN/
WRN
2
ON test port PCSSpp r 3
1281 NPE Crosstalk (#6) MAJ/MIN/
WRN
2
ON test port PCSSpp r 3
1537 Any Port Diagnostic
(#35)
MAJ/MIN/
WRN
2
OFF test port PCSSpp r 3
1793 (m) 57489 None None