DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-324reset spe-standby
8
Help Messages
If the system technician presses HELP after entering "reset spe-standby" on a
duplex SPE system, the following message will be displayed:
Enter standby SPE recovery level ’1’(WARM), ’2’(COLDII),
’3’(COLDI), ’4’(REBOOT) or ’5’(EXT REBOOT)
Error Messages
If the specified level is invalid (not 1-5), the following message will be displayed:
System reset level invalid
If the standby SPE is not refreshed and the SPE Select switches are selecting the
active SPE, the following message will be displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is not refreshed; the following message will be displayed:
Standby SPE memory not refreshed; use the
"refresh spe-standby" command
Output
If the reset command is successful, the following message displays:
Command successfully completed
If the reset command is unsuccessful, the following message displays:
Standby SPE failed to reset with requested level;
check for STBY-SPE errors
If the standby is in the process of doing a software upgrade, then the following
will be displayed:
Standby SPE upgrade in progress, command denied
3Cold-1
4 Reboot
5 Extended Reboot
Level Recovery