DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-494DIG-LINE (Digital Line)
10
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call. Use
display port UUCSSpp/PCSSpp to determine the
station extension or attendant number of the port. Use
status station or status attendant to determine the
service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. (See Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids", for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is
not busied out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1392 ABORT This port is currently a TTI port and the test will not
execute on it.
1. Verify that the port is a TTI port using either the
display port command (the display shows that the
port is a TTI port) or the list config command (the
display shows a t for the port).
2. If either list config or display port indicates that the
port is
not
a TTI port, escalate the problem. If both
commands indicate that the port is a TTI port, the
abort is correct, and no action is necessary.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-133. TEST #16 DIG-LINE Station Lamp Updates Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page