DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-94disable test-number
8
disable test-number
This command stops a specified test number from being performed during
demand and periodic or scheduled maintenance.
Synopsis
disable test-number number
[ print | schedule ]
Permissions
The following default logins may execute this command: inads, init.
Examples
disable test-number 710
disable test-number 710 print
disable test-number 510 schedule
Description
The disable test-number command makes the user specified test number
unavailable for any maintenance testing. An enable test-number must be issued
to make the test number available.
Parameters
Help Messages
If the system technician presses HELP after entering "disable test-number," the
following message will be displayed:
Enter test number
number The number of the test that is to be maintenance disabled.
print If specified, this parameter will cause the information displayed by this
command to be sent to the printer attached to the terminal as well as to
the screen.
schedule When the "schedule" option is specified, the command is validated and
then a scheduling form is displayed to allow the technician to schedule
execution of the command. The command is then placed in the
command queue and is executed at the specified time. The information
displayed by the command is sent to the system printer instead of the
screen. Refer to the Report Scheduler and System Printer feature
specification [1] for more details.