DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-651ETR-PT (Enhanced Tone Receiver Port)
10
Table 10-188. TEST #43 Tone Detector Audit/Update Test
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources
needed for this test.
1. Wait 1 minute, and repeat the command a maximum
of 5 times.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Hardware audit failed.
1. Run the short test sequence via the test port
PCSSpp sh r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In
order to restore system performance to normal,
replace the circuit pack containing the defective
ETR-PT. Follow the procedures described in the
TONE-BD section for replacing a tone/clock circuit
pack.
PASS The ETR Port has passed the sanity inquiry.
Continued on next page