DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1443TIE-DS1 (DS1 Tie Trunk)
10
1004 ABORT Far end is seizing the trunk while the test is ongoing. A
glare situation is detected. Current test is designed to
be aborted. Use the display port UUCSSpp command
to determine the trunk group/member number of the
port. Use the status trunk command to determine the
service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT Test failed due to incompatible configuration
administered in trunk group form.
1. Verify the following fields on the trunk group
administration screen:
a. Is trunk direction incoming only?
b. Is trunk outgoing type either automatic or
immediate-start?
c. Is trunk the 24th port of the DS1 Interface circuit
pack while common control channel signaling is
specified?
2. If the trunk has been administered using the above
information, then this test should abort.
1018 ABORT The test was disabled via translation. You may want to
determine why the test has been disabled before you
enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk
Administration’ screen is set to ’n.’ To enable the
test, change the trunk administration and enter ’y’
into the ’Maintenance Test’ field.
2. Repeat the test.
Table 10-440. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page