Maintenance Object Repair Procedures
Page 10-323CO-DS1 (DS1 CO Trunk)
10
a. The trunk direction is administered as an incoming only trunk.
b. The trunk has been seized by a normal trunk call.
c. The trunk is administered with maintenance test disabled.
Table 10-91. TEST #314 DS1CO Dial Tone Seizure Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The test was aborted because system resources
required to run this test were not available. The port may
be busy with a valid call. Use the display port PCSSpp
command to determine the trunk group/member number
of the port. Use the status trunk command to determine
the service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the error log table for a description of this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at
1-minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1004 ABORT The test was aborted because the port was seized by a
user for a valid call. Use the display port PCSSpp
command to determine the trunk group/member number
of the port. Use the status trunk command to determine
the service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at
1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page