DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1467TIE-TRK (Tie Trunk)
10
The Tie Trunk Dial Test seizes the trunk and outpulses a pause digit.
For a port administered as TGU or a TGE, the Seizure Test internally seizes the
trunk and outpulses a "pause." The report reports the result of the seizure attempt
uplink.
Table 10-445. Seizure Tests (#73, #747, #73)
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The trunk may be busy with a valid call. Use
the display trunk xx to determine the trunk
group/member number of the port. Use the status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active, but the port is not in use
(no calls), then check the Error Log for Error Type
1025 (see Error Log table for description of this error
and required actions). The port may be locked up.
The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page