DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-689upgrade software
8
Initcauses
Executing "display initcauses" shows that software upgrade and the level of
system reset being done.
Multi-user Contention
When this command is executing, all other maintenance commands will be
blocked. Exceptions to these are most of the status or display type commands.
All administrations commands are not blocked. It is the user’s responsibility to
make sure that no new translations are added between the last save translation
operation and the completion of the
upgrade software
command.
Recent Change History Log
The
upgrade software
command will not be logged for both simplex and duplex
systems. This is due to the clearing of memory during the level 4 reset.
Periodic and Scheduled Maintenance
Periodic and scheduled maintenance will be suspended while the upgrade
command is executing.
Error and Alarm Log
Error and alarm logs before the software upgrade will be lost.
Demand Busyout Objects
Maintenance objects that have been demand busyout will be released when the
processor reboots or interchanges during the software upgrade. If the command
is cancelled before the actual reboot or interchange starts, then all demand
busyout objects status will be preserved.
Standby SPE Maintenance
Data consistency alarms will be generated if the software in the active and
standby are not consistent.
Disabled Objects
All disabled objects retain their "disabled" status after a software upgrade
according to status recorded in the last successful