Maintenance Object Repair Procedures
Page 10-52ANL-16-L (16-Port Neon Analog Line)
10
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Look for TONE-PT errors in the error log. If present, refer to the
TONE-PT Maintenance documentation.
2. If there are no TONE-PT errors in the error log, retry the test at
1-minute intervals for a maximum of 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Issue the display port and the status station commands to
determine if the station is idle. If the station is found to be idle, issue
the test port command for this port.
2. If the test continues to fail, issue the busyout port and the release
port commands, and then retest the port.
3. If the test still fails, replace the board.
PASS The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using other port tests and
by examining station, trunk, or external wiring.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 10-21. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page