DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1651VC-LEV (Voice Conditioner DSP Port Level)
10
Error Log Entries and Test to Clear Values
Notes:
a. The number of VC resources in the system that are in service has fallen
below the calculated minimum value. If the number of in-service VC ports
falls below the MMCH port capacity (value entered in the Minimum
Maintenance Threshold VCs field on the system parameters maintenance
form), a VEC-LEV error is logged. If this outage continues for 15 minutes a
MAJOR alarm is raised. To resolve this alarm, correct the out-of-service
problem by following the procedures below:
1.See “VC-DSPPT” and “VC-BD” and resolve any associated alarms.
2.If a VC-LEV error/alarm exist and none has been raised against VC-BD
or VC-DSPPT maintenance objects, a VC circuit pack may have
been removed from service causing the VC-LEV error/alarm. To
resolve a VC-LEV MAJOR alarm, restore the number of VC ports
available for service to be equal to or more than the calculated port
capacity. See “Resolving VC-LEV ERRORS/ALARMS” for details.
System Technician-Demanded Tests:
Descriptions and Error Code
There are no System Technician-Demanded test for VC-LEV.
Table 10-484. VC-LEV Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/ Off
Board Test to Clear Value
1 (a) Any None MAJOR OFF