DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-190BRI-SET, ASAI-ADJ, BRI-DAT
10
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with certain Layer 3 messages have expired before a
required response was received. In the following table, the aux data field
indicates which timer has just expired. (For more information, refer to the
AT&T ISDN-BRI Specification.)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
3073(j) 0 BRI Remote
Loop Back
(#627)
WARNING OFF test station
ext l r 2
test
data-module
ext l r 2
3329(k) Any Signaling
Link Status
(626)
WARNING MAJOR/
WARNING
2
OFF †
3584 0, 1 None
3585-
3839(i)
0None
3840-
4095(m)(n)
0None
Aux Data Timer Type
2 First T303 (SETUP timer)
3 Second T303 (SETUP timer)
4 T305 (DISConnect timer)
5 First T308 (RELease timer)
Table 10-63. BRI-SET/ASAI-ADJ Error Log Entries — Continued
Error Type
Aux
Data
Associated
Test
Alarm
Level
BRI-PORT
Alarm Level
ABRI-PORT
ATT-PORT
LGATE-PORT
ATTE-PT
On/
Off
Board
Test to Clear
Value
Continued on next page